DaVinci Slate Technical Specifications and Documents
DaVinci Slate is installed following standard industry practices. No special training or handling is required for the contractor or builder. Download the comprehensive Installation Guide for details and instructions to guide you through every step of the installation process. If you have questions or require further information, please contact our Sales Associates for any additional help.
Shingle Dimensions |
| Widths |
12", 10", 9", 7", 6" |
|
Thickness at Butt |
1/2" |
| Length |
18" |
|
Thickness at Tip |
1/8" |
Hip - Ridge - Starter |
|
6" Hip & Ridge
(for ridge vents only) |
7" Hip & Ridge
(standard) |
12" Starter |
Pieces/Bundle |
20 |
20 |
20 |
Lineal Ft / Bundle |
5* |
5* |
20 |
Pieces / Lineal Ft |
4* |
4* |
1 |
*At recommended 6” exposure.
**Starter Shingle is 3/8” at butt.
Note: 9” pieces available for ridge; 4” pieces available
for turrets. |
|
Field Shingles per Roofing Square |
| |
| Coursing |
Roof Pitch |
Max. Exposure |
Bundles/Square |
Shingles/Square |
Weight/Square |
| Straight |
6:12 or greater |
7.5" |
7.00 |
210 |
273 lbs |
| Staggered |
6:12 or greater |
7.0" |
7.50 |
225 |
293 lbs |
| Straight or Staggered |
Less than 6:12 |
6.0" |
8.75 |
262 |
342 lbs |
Note 1: All calculations are based on using the recommended 3/8" gap between shingles.
Note 2: Straight coursing may be used at any exposure up to 7.5”;
and staggered coursing may be used at any exposure up to 7.0”. |
Packing and
Shipping Information |
|
Testing Summary |
| |
# Shingles |
Weight |
|
Type of Test |
Standard |
Results |
| Per Bundle* |
30 |
39 lbs |
|
Fire Test |
ASTM E 108 |
Class A |
| Per Pallet** |
1,440 |
1,872 lbs |
|
Impact Test |
UL 2218 |
Class 4 |
| Per Truckload*** |
34,560 |
44,928 lbs |
|
Wind Test |
ASTM D 3161 |
Certified to 110 MPH |
*All weights are approximate
**48 Bundles per Pallet
***24 Pallets per Truckload |
Building Code Approvals:
ICC-ES ESR-2119, Miami Dade County, FL NOA No. 06-308.03 Exp. 7/12/12 and TDI |
|
|