DaVinci Shake Technical Specifications
DaVinci Shake is installed following standard industry practices. No special training or handling is required for the contractor or builder. Download the comprehensive Installation Guide for details and instructions to guide you through every step of the installation process. If you have questions or require further information, please contact our Sales Associates for any additional help
Shingle Dimensions |
| Widths |
9", 8", 7", 6", 4" |
|
Thickness at Butt |
5/8" |
| Length |
22" |
|
Thickness at Top |
1/4" |
Hip - Ridge - Starter |
| |
6" Hip & Ridge
(standard) |
One-Piece Hip & Ridge |
12" Valley Shingle |
12" Starter |
| Pieces/Bundle |
20.0 |
10 |
10 |
20 |
| Lineal Ft / Bundle |
8.33* |
8.33* |
4.3* |
20 |
| Pieces / Lineal Ft |
2.40* |
2.40* |
2.3* |
1 |
| *At recommended 10" exposure. |
|
Field Shingles per Roofing Square |
| Roof Pitch |
Coursing |
Max. Exposure |
Bundles/Square |
Shingles/Square |
Weight/Square |
| 4:12
or greater |
Straight |
10" |
8 |
200 |
304lbs |
| 4:12
or greater |
Staggered |
9" |
9 |
225 |
342lbs |
Note 1: All calculations are based on using the recommended 3/8" gap between shingles.
Note 2: Felt interlay is suggested on any pitch and required on pitches less than 6" in 12". |
Packing and
Shipping Information |
|
Testing Summary |
| |
# Shingles |
Weight |
|
Type of Test |
Standard |
Results |
| Per Bundle |
25 |
38 lbs |
|
Fire |
ASTM E 108 |
Class A or Class C* |
| Per Pallet** |
1,200 |
1,824 lbs |
|
Impact Test |
UL 2218 |
Class 4 |
| Per Truckload*** |
28,800 |
43,776 lbs |
|
Wind Test |
ASTM D 3161 |
Certified to 110 MPH* |
*All weights are approximate
**48 Bundles per Pallet
***24 Pallets per Truckload
|
*See DaVinci Installation Instructions for details.
Building Code Approvals:
ICC-ES ESR-2119, Miami Dade County, FL NOA No. 07-1203.03 exp. 2/21/13 and TDI |
|
|